Application:The pilot-scale bioreactor is suitable for processes of pilot-scale microbial fermentation production, and the production-scale bioreactor is suitable for large-scale microbial fermentation production.
Design concept: The design of the system meets the technical requirements of modern microbial fermentation tanks. The system integrates all essential components, and uses high-quality sanitary accessories to ensure the best performance and high safety of operation. The system adopts open frame design, including all pipelines, supply systems and individual upright tanks. The supporting pipelines are manufactured and installed on site according to the customer's manufacturing process requirements.
Tank Volume:20L, 30L, 30L, 50L, 75L, 100L, 150L, 200L, 300L, 500L, 1000L, 2000L, 3000L
Material of construction: For parts in contact with the culture media, SUS316L stainless steel is used stainless steel parts, tempered borosilicate glass is used for non-stainless steel parts, and the sealing material is made of EPDM or silicone that meet FDA requirements; the non-contact part is made of SUS304 stainless steel.
Specifications
Specifications | |
Tank Volume | 20 L, 30 L, 40 L, 50 L,75 L, 100 L, 150 L, 200 L, 300 L, 500 L, 1,000 L, 2,000 L : 3,000 L, 5,000L |
Temperature | Automatic control (electric heating blanket), display range 0-150°C, resolution 0.1° C, control accuracy ± 0.2 |
Air | Automatic control of air, carbon dioxide and oxygen with calorimetric mass flowmeter, nitrogen with rotor flowmeter |
Air Supply | L tube macro sparge (other air supply methods are optional) |
DO electrode | Mettler/Hamilton optical digital electrode, display range 0-200%, resolution 0.1%, control accuracy ± 2% |
pH electrode | Mettler/Hamilton digital electrodes, display range 2-12, resolution 0.01pH, control accuracy ± 0.02 |
Peristaltic pump | Configuration of 2-4 Waston-Marlow peristaltic pumps, automatic control of feeding according to different requirements |
Agitation | Automatic control, display range 0-1,000 rpm (adjust to the size of the tank), resolution 1 rpm, control precision 1 rpm (adjust to the size of the tank) |
Blade | Blade angle and size customizable |
Antifoam/liquid level electrode | Automatic level control and addition of antifoaming agent (optional) |
Cooling | Cold water Solenoid Valve with stainless steel cooling sleeve (optional) |
Weighting | Mettler weighing module (optional) |
Tags
Copyright © Shanghai Duoning Biotechnology Co., Ltd. All Rights Reserved Sitemap | Technical Support: